HMS BACnet Modbus gateway

Connecting devices with a Modbus-RTU or Modbus TCP interface The Anybus BACnet to Modbus gateway allows Modbus devices to communicate on a BACnet network. The gateway works as a translator between the two networks allowing Modbus RTU, ASCII or TCP-d...

Request quote

Connecting devices with a  Modbus-RTU or Modbus TCP interface The Anybus BACnet to Modbus gateway allows Modbus devices to communicate on a BACnet network. The gateway works as a translator between the two networks allowing Modbus RTU, ASCII or TCP-devices to show up as individual BACnet-compliant devices on a BACnet/IP network. This enables central control and supervision of Modbus devices in a building for example.

Where BACnet is used   BACnet is a data communication protocol mainly used in the building automation and HVAC industry (Heating Ventilation and Air-Conditioning). The most common serial version is called BACnet MS/TP while the dominant Ethernet version is BACnet/IP. Modbus remains a popular protocol. It is frequently used on mechanical equipment: - Boiler controls     - Variable speed drives     - Metering applications

Modbus is simple to use but not BACnet compliant. This is where a gateway between Modbus and BACnet is needed!

How it works Modbus RTU and Modbus ASCII networks are connected to the serial port of the gateway, while Modbus TCP and BACnet/IP networks are connected to the Ethernet port. You will need to create a device profile for each Modbus device and upload this to the gateway.

 KEY FEATURES AND                              BENEFITS
    Handles conversion between Modbus (RTU, ASCII, TCP) and BACnet/IP
    Connects up to 30 Modbus serial devices to BACnet (processing up to 1000 Modbus registers).
    Each connected Modbus device appears as an individual BACnet compliant device
    Excel tool and instructions for creating Modbus Device Profiles are available
    A resident web server allows for commissioning, and troubleshooting via a standard web browser
    Comes in a rugged IP30 metal housing that mounts on 35-mm DIN-rail
    A reset switch is provided for returning to the factory default IP address if required
    LED indicators provide communication status on both the Ethernet and serial ports
    External terminating resistors are included in the package. (No termination by default in the product.)
    Global free technical support and consultancy
    3 year product guarantee from date of shipment