IP66 / 67 Explosion-proof flow rate indicators / totalisators (E-series)

IP66 / 67 Explosion-proof flow rate indicators / totalisators (E-series)

The E-series offers unparalleled safety and ease of use, opening covers is a thing of the past. The touch-through glass makes operation without interruptions possible. The E-series saves time, money and hassle and delivers user-friendliness in the toughest conditions.

Benefits
• Save time and get flexibility with the easy to operate via touch-through glass: there is no need to remove the front or to arrange a work permit.
• Intuitive configuration menu "Know one, know all!" Saves time, costs and aggravation.
• Cost effective with an easy-to-install, spacious room, plug and play connectors and 1 ”NPT thread for flow meter mounting.
• Durable high-quality stainless steel 316L Ex d housing for extremely salty atmospheres (offshore).

PDF logo E-series brochure PDF logo Reference Guide Request for quotation


E018 E018 Explosion proof - Flow rate Monitor / Totalizer - with linearization, high / low alarms, analogue and pulse outputs & HART Communication

The E018 is one of the top models in our range of explosion-proof flow computers. In addition to the average K factor, 16 linearization points can be entered. The unit interpolates between these points, significantly improving accuracy in each current range. In addition, a continuous flow monitoring function is available with high and low flow alarm values ​​and four alarm outputs. The E-series distinguishes itself through its high-quality production and its functionality-driven European design.

Application: Flow measurement with mechanical flow meters, where retransmission of the totalizer, monitoring of the flow and HART communication is required.

PDF logo E018 Datasheet


E110 E110 Flow rate indicator / totalizer with analog and pulse signal outputs

The E110 is a popular model in our range of explosion-proof flow indicators / transmitters, complete with pulse and analog output signals. The E-series distinguishes itself through its high-quality production and its functionality-driven European design. We believe that it is not only about meeting the requirements for explosion-proof, but also about safety during daily use.

Application: Liquid flow measurement where retransmission of the flow rate and / or totalizer functions or serial communication is required.

PDF logo E110 Datasheet


E112 E112 Flow rate indicator / totalizer with linearisation, analogue and pulse outputs

The E112 is a popular model in our range of explosion-proof flow indicators / transmitters. In addition to the average K factor, 15 linearization points can be entered. The unit interpolates between these points, significantly improving accuracy in each current range. The E-series distinguishes itself through its high-quality production and its functionality-driven European design. We believe that it is not only about meeting the requirements for explosion-proof, but also about safety during daily use.

Application: Flow measurement with mechanical flow meters where accurate calculation over the entire measuring range is required.

PDF logo E112 Datasheet


E115 E115 Bi-directional flow rate indicator / totalizer - with analog, pulse and current direction outputs

The E115 has been developed for applications where the flow direction is a problem. Applications can be found by loading and unloading ships using a bi-directional flow meter. Another application is the correction of back flow due to shocks in a pipeline caused by piston pumps or valve behavior. It is required to provide two pulse signals from the flow meter that are 90 ° or 270 ° degrees out of phase.

Application: For bi-directional flow measurement applications such as loading / unloading (from ships) via the same flow meter.

PDF logo E115 Datasheet


E126EG E126-EG Flow computer - with temperature and pressure compensation for corrected gas volume

The robust E126-EG has been designed with a focus on your safety. It goes beyond complying with the regulations for approvals of hazardous environments, because the environment is often much more difficult than explosion-proof requirements require. Are you experiencing errors in your processes due to rain, snow, salty atmospheres (offshore) or early wear? The E126 delivers accurate measurements and can withstand the toughest conditions.

Application: flow measurement in applications where calculation of the net gas flow under basic conditions is desired.

PDF logo E126EG Datasheet


E126EL E126-EL Flow computer - with temperature compensation for corrected fluid volume

The robust E126-EL has been designed with a focus on your safety. It goes beyond complying with the regulations for approvals of hazardous environments, because the environment is often much more difficult than explosion-proof requirements require. Are you experiencing errors in your processes due to rain, snow, salty atmospheres (offshore) or early wear? The E126 delivers accurate measurements and can withstand the toughest conditions.

Application: current measurement in applications where calculation of the net current at basic conditions is desired without the influence of thermal product expansion

PDF logo E126EL Datasheet


Call me