IP67 Field or panel mounting, extended and robust (F series)

IP67 Field or panel mounting, extended and robust (F series)

The F-series is your first and safest choice when mounting in the field for safe and dangerous environmental applications. Especially in harsh weather conditions such as rain, snow, salty atmospheres and temperatures between -40 ° C to + 80 ° C.

Benefits:
• Robust IP67 (NEMA Type4X) field housing. It is so robust, you can even stand on it!

• Intrinsically safe available - ATEX, IECEx, FM and CSA approval for gas and dust applications.
• Programming can be done by your own staff, with the logical menu-driven structure,
saves costs and irritation. Know one, know them all!

• Very diverse mounting options: wall, pipe, panel mounting or directly on the flow meter

Image result for PDF logo

Brochure F seriesPDF logo Reference Guide Request for quotation


F070 F070 Level indicator - with large characters

The F070 is an uncomplicated level indicator with large 26 mm (1 ") high digits. The indicator can be set to display the level as a quantity, height or percentage. The unit of measurement to be displayed is easily selected via an alphanumeric configuration menu No self-adhesive labels are needed on the outside, and the housing is applied: a weather-resistant and user-friendly solution!

Application: applications where a basic level measurement is required without level monitoring, linearisation or signal transmission.

PDF logo F070 Datasheet

 


F073 F073 Level monitoring - with high / low alarm output

The F073 is a versatile level indicator with continuous level monitoring. It offers the possibility to set one low level and one high level alarm value. If desired, an ignore function can be set to allow an incorrect level during a certain period. The configuration of the range, the offset and the number of decimal places is done via software functions, without sensitive DIP switches or trimmers.

Application: level measurement where continuous level monitoring is important without signal transmission.

PDF logo F073 Datasheet

 


F074 F074 Level / pump controller - with one control output

The F074 is a basic level / pump controller that works with a preset value and two switching points to control a pump or valve. The low and high level switching points are entered as a percentage of the preset value to switch the device on / off. For pump control applications, the function can be reversed to empty a well. The result is a stable level within a hysteresis around the preset value.

Application: Basic on / off level control applications without PI (D) control requirements. Also very suitable for applications where the required level changes regularly. Another possible application is filling a container or emptying a well or tank.

PDF logo F074 Datasheet

 


F077 F077 Level monitoring - with linearization and one high / low alarm output

The F077 is a versatile level indicator with linearization and continuous level monitoring. In addition to the average span, eight linearization points can be entered to compensate for the shape of the tank. The unit interpolates between these points to increase accuracy. A low level and a high alarm level can be set with the level monitoring function.

Application: level measurement where continuous level monitoring and linearization of the tank shape is important without signal transmission.

PDF logo F077 Datasheet

 


F170 F170 Level monitoring - with high / low alarms and analog outputs

The F170 is a versatile level indicator with continuous level monitoring. It offers the possibility to set two low and two high alarm values. If desired, an ignore function can be set to allow an incorrect level during a certain period.

Application: Level measurement and continuous level monitoring is required, as well as signal transfer of the level or serial communication.

PDF logo F170 Datasheet

 


F173 F173 Level monitoring - with linearization, high / low alarms and analog outputs

The F173 is a versatile level indicator with linearization and continuous level monitoring. In addition to the average span, fifteen linearization points can be entered to compensate for the shape of the tank. The unit interpolates between these points to increase accuracy. This linearization influences all displayed information, as well as the alarm and analog outputs.

Application: Level measurement where linearisation of the tank shape and continuous level monitoring is important, as well as signal transmission of the level or serial communication.

PDF logo F173 Datasheet

 


F190 F190 General purpose monitor - with analog and high / low alarm outputs

The F190 is a versatile indicator for general use with continuous monitoring function. In addition to the focus on level, temperature and pressure applications, it also contains a series of other units of measurement and even the possibility of a custom unit with max. 8 characters.

Application: for monitoring a wide range of process parameters such as flow (linear or square root), level, pressure and temperature measurements, even with signal transfer or serial communication available.

PDF logo F190 Datasheet


 

Please accept cookies to help us improve this website Is this OK? Yes No More on cookies »